How to clean the pneumatic ball valve correctly

Classification:common problem Release time:2021-05-11 26 Article source:common problem Release time:2021-05-11        26

After the pneumatic ball valve is used for a long time, the performance of the pneumatic ball valve will decline significantly. What are the reasons for this situation? In fact, the reason for this situation is that the pneumatic valve is not cleaned in time, so how can we correctly clean its pneumatic ball valve?

Larger flow volume of electric cut-off ball valve: due to its streamline, out of line and full right angle rotation control, the larger value of volume is particularly high, the flow capacity is particularly large and the flow resistance is small. Therefore, a smaller and more economical valve size can be used. Pneumatic knife gate valve is a right angle rotary regulating valve, which is used together with the valve positioner. Greater reliability (safety) of pneumatic cut-off valve: the valve body is an integral structure, firm and durable, the operation is not affected by pipeline pressure, and the leakage of valve body can be avoided.

1. Purging pressure management

General enterprises shall not have more than one pipeline information system research work environment pressure, which shall not be significantly lower than 25% of the social work and life pressure, and the pipeline design in large cities shall not be lower than 0.6MPa.

2. Purging method

It can be determined according to the technical requirements for the use of the valve control pipeline, the types of different media for drug delivery in the pipeline and the degree of dirt on the inner surface of the pipeline. The purging sequence is generally developed according to the main pipe, branch pipe and drainage pipe.

3. During purging, except for non-ferrous metal and non-metallic pipes, hammer shall be used to knock the pipe wall, especially for welds, dead corners and pipe bottom parts, but there shall be no tissue damage and pipe damage.

4. During purging, it is required until a kind of clean water is discharged from the pipe. When purging with compressed Chinese air, ensure that the medium mass flow rate in the network system is not less than 20m / s. place white paper or white cloth at the outlet for product inspection. It is qualified if there is no rust, dust pollution and other dirt marks on it within 5min.

5. After the purging is qualified, carefully study and fill in the purging record, and note that in addition to the inspection of relevant regulations and the restoration of normal work, no analysis shall be carried out to affect other student operations in the management of the company.

6. The pipe fittings that are not allowed to be purged in the valve pipeline safety system, such as throttle valve, instrument, filter, check valve, etc., shall be temporarily removed for safekeeping, temporarily connected with a short pipe, and re installed after the purging is qualified. The construction of equipment and pipelines that are not allowed to be purged shall be isolated from the risk of purging system.

Therefore, when cleaning the data of pneumatic ball valve, enterprises need to follow reasonable steps, so as to ensure good cleaning effect.